Voltage stabilizer Operational use Eight hour working day

AC contactor which is the basic duty. Contactor Conventional thermal current parameters is determined Click duty, under normal circumstances the specifications of various series contactors are Inverter Power Supply suitable for eight hour working day. Such duty contactor which closes the main contact in the case of thermal equilibrium can be achieved by the rated current, but after eight hours should be divided.
Uninterrupted work system
Such work system is a long-term work system, that is the main contacts remain closed for the duration of carrying a steady current of more than eight hours (a few weeks or even years) is not breaking current working system. Contacts in the contact oxidation and long-term accumulation of dust in working condition electric transformer unchanged easy voltage stabilizer, these factors will lead to the deterioration of thermal conditions, phase to phase, relatively insulated reduce creepage phenomenon even prone to short-circuit. When the conditions required to work in this type of work contactor system, AC contactor must derating or special design, easy to gather dust should use, creepage distance between the larger models. Dusty and corrosive gas environment should pay special attention to this issue.
Short-time working
In contact with the main contact system under this type of work remain closed is not enough time to make contacts to reach thermal equilibrium, there is no load load periods separated by periods, while the load time enough to make contact with the temperature back to the initial state temperature (ie cooling medium temperature). Energy Meter Short-time working contactor contacts energizing time standard value 3,10,30,60 and 90min.

2015年2月4日星期三

electric energy meter Intermittent periodic duty

Intermittent duty cycle is repeated short-time working means contactor closing and opening times are too short to make contacts in the working system to reach thermal equilibrium. mcb circuit breaker Obviously the main factors affecting the life time of such contacts is the cumulative number of operations. The main parameters describing intermittent duty cycle is powered sustained rate and operating frequency, power continued to rate the standard value of 15%, 25%, 40%, 60% of four, the operating frequency is divided into eight (1,3,12 , 120,300,600,1200) electric energy meter, each level figures mean that the number of hourly operating frequency of the contactor rated. Typically operating frequency of 100 times / h or more devices are heavy duty equipment, machine tools typical equipment (vehicles, drilling, milling, grinding), lifting equipment, mill equipment, centrifuges, coking industry, coke oven car is heavy intermittent periodic duty tasks. Operating frequency Inverter Power Supply over 600 times / h belongs to special equipment heavy duty equipment, such equipment is mainly some devices similar to my company unloading port lifting equipment and machine rolling on.

2015年2月1日星期日

Voltage stabilizer Different requirements analysis

Different operating system of exchanges and contacts made entirely different requirements, focusing face when considering the choice of a different Switchgear & Substation nature. When the "voltage stabilizer" and "short-time working" equipment selection is subject to fewer constraints contact, just consider the contactor rated operating current can be greater than the actual, proper equipment is important when you put a little margin. The ability to "stop work" system should first consider equipment selection contacts Dust-creepage prevent overheating, compact structure should not use contactor (circuit breaker for use when necessary). To prevent overheating, the contactor should enlarge the Power Supply capacity of more than 20% of large chemical plant electrical equipment mostly this is the case. We must first consider the mechanical life of electrical contacts and operating mechanism of life belonging to heavy duty and special heavy task of "intermittent periodic duty" equipment selection contactors should be used CJ12 series (especially suitable for winding motor), CJ20 series or series of vacuum contactors, due to derating can greatly improve the electrical contactor life can easily be selected as the starting mcb circuit breaker current of the motor contactor rated current to improve the safety and reliability of production unit.

2015年1月29日星期四

electric energy meter Energy-saving technology

AC contactor AC contactor is widely used in low voltage circuits, is a safe, easy to control, CNC Electric volume and a wide range of industrial necessities. Now commonly used in the rated current 63A and above large, medium-capacity AC contactor should more than million Taiwan dollars electric energy meter, its operating system at the time of retention of electromagnetic active power consumed between 10W ~ 100W; reactive power consumed in the Dole circuit breakers spent tens to hundreds of spent between Seoul. The active power consumption distribution is roughly: 65% to 75% of the core, the short-circuit ring 25% to 30%, the coil 3% to 5%. For such a being in the industrialization and urbanization of exchanges and contacts with large country, and the energy needs of the growing tension, saving power resources has become imperative.
Such as the AC contactor solenoid operating system with an appropriate energy-saving technology to its operating system, the original design of electromagnetic ac to dc retention retention, core and short ring can save most of the loss in power, to obtain a high energy-saving efficiency (typically active saving rate> 90%). Moreover, through the Switchgear & Substation transformation can reduce or eliminate noise, reduce the temperature rise of the coil and extend the service life of the contactor.

2015年1月26日星期一

Voltage stabilizer Energy-saving products Categories

AC contactor mainly depends on its energy-saving program works and the corresponding structure processes. Fat suction within the electromagnetic AC contactor by Circuit Breakers constant component F0 and F ~ alternating component composition. Among them:
Constant component: F0 = Fatm / 2 (Fatm = 107 B2 MS / 8π)
Alternating component: F ~ = F0 cos 2ωt.
At work, due to the armature reaction force always been the role of the spring, the contact springs Fr reaction force, the electromagnetic suction averages Fat> Fr; when Fat <Fr armature at the beginning of the release voltage stabilizer, Fat> Fr armature also was attracted state, so Again and again, the armature vibration and noise. At this point in the alternating magnetic core produced by hysteresis loss and eddy current loss will cause the core heat (superposition of silicon can play a role in reducing the eddy current losses). To reduce operating noise is usually electri calmete open in the small capacity of the electromagnetic system yoke ends embedded in a small groove corresponding short-circuit ring, and its role is to be divided into two parts by the core flux, that does not pass through the magnetic flux Φ1 and short-circuit loop the magnetic flux Φ2 through the short-circuit loop, and Φ2 lag Φ1, suction is always greater than the synthesis reaction, thereby reducing the vibration and noise, but also increases the copper loss accordingly.
AC contactor power mainly by the retention power and pull the power of two parts, although larger coil pull starter instant power, but time is very short (tens of ms); working time has been in the retention hold (at this energy loss is mainly concentrated in the state of retention on iron loss). That is why if they can reduce the AC contactor work retention can save energy consumption, CNC Electric according to this principle, the current energy contacts broadly categorized as follows.

2015年1月23日星期五

Voltage stabilizer Coil-saving and Saver

Saver is divided into: capacitive, transformer, duty cycle (change) type. AC contactor Saver corresponding supporting the use of the contactor in the DC state retention operation, air circuit breaker so to save energy. Saver AC contactor solenoid due to electromagnetic energy and the internal device Saver limitations generally applicable to the rated current of 60 ~ 600A AC contactor, lower than 60A AC contactor because the stored electromagnetic solenoid can run in DC maintain its pull; electromagnetic greater than 600A AC contactor can be easily generated so Saver damage internal components voltage stabilizer.
Contactor coil AC passed, it will produce a corresponding inductance, inductive influence of the size of the size of the current in the coil, AC solenoid coil inductance, the core is not closed when the inductance is small, a large current through , which is caused by the coil in the suction power of the largest timely reason. Circuit breaker When the AC contactor pull into the retention time, due to long-term work in the state coupled with the coil power consumption, temperature rise. AC contactor usually work long hours can produce 50 ℃ ~ 60 ℃ degree heat, the summer plus 30 ℃ ~ 40 ℃ ambient temperature of the coil temperature rise faster. Coil long period of high temperature operation, will accelerate the aging and even burned, AC contactor life will be shortened.
According to AC contactor coil power consumption characteristics of fast rise, by reducing the power consumption and temperature to save energy. According to the internal structure, saving coil is divided into: double winding type, current limiting resistor, double winding self-conversion conversion type and location. Works will use energy-saving coil is usually on its pulsating DC coil retention program run: pull winding generally larger diameter, fewer turns, and thus lower impedance, resulting pull current large; retention winding general smaller diameter, number of turns, current transformer the impedance of large, small and therefore holding current. Corresponding increase rectifiers and varistors and film capacitors, the AC contactor is energized to work in DC state, large starting current to ensure a reliable pull-electromagnetic systems, smaller holding current to reduce the retention power, thereby reducing the electrical losses and electromagnetic coil temperature of the system.
Energy-saving AC contactor
According to AC contactor structure, increasing as Power Saver, saving coil, mechanical locking device, electromagnetic system to the remanence (permanent magnet) retention type, etc., can play the energy saving effect. After contact with the tradition of saving energy, such as shown in Table 2.
Traditional CJ10, CJ12, CJ20 AC contactor, for example, for energy saving before and after comparison of the data, reflecting the energy saving effect.
In CJ20 / 400A / 3 year energy savings calculation: saving work properly before the contactor holding power for 180W, priced according to the average electricity tariff by 1 yuan / Kwh meter, working hours 12h / day:
Total power consumption before saving: 0.18Kw × 12h × 365 = 788 Kwh
After saving the total power consumption: 0.006Kw × 12h × 365 = 26 Kwh
Saving (annual electricity): 788Kwh - 26Kwh = 762Kwh
Cost-saving: 762Kwh × 1 元 / Kwh = 762 元
At present, energy-saving AC contactor has a certain market, but not enough popular, traditional exchanges and contacts currently in use on the dominant user. The main reason is the energy-saving type contactors expensive, the user can not accept the one-time investment, to be national policy to electric meter increase efforts on the promotion of energy-saving contacts, promote the wide application of energy-efficient contactors....

2015年1月20日星期二

electric energy meter Thyristor inverter circuit

Thyristor inverter circuit to convert the direct current into alternating current, which corresponds to a reverse process of the rectifier, is defined as an inverter. For example: power transformers The thyristor electric locomotives electric energy meter, when the DC motor as a generator downhill braking operation, the locomotive of potential energy into electrical energy, trans go to the AC grid. Another example is the operation of a DC motor, brake to make it quickly, but also allows the motor as a generator to run the motor kinetic energy into electrical energy, anti-delivered to the grid. The converter operates in inverter state, if the converter is connected to the AC side of the AC power to DC to AC inverter with a Circuit breaker frequency counter to the grid to go, called active inverter.