Different operating system of exchanges and contacts made entirely different requirements, focusing face when considering the choice of a different Switchgear & Substation nature. When the "voltage stabilizer" and "short-time working" equipment selection is subject to fewer constraints contact, just consider the contactor rated operating current can be greater than the actual, proper equipment is important when you put a little margin. The ability to "stop work" system should first consider equipment selection contacts Dust-creepage prevent overheating, compact structure should not use contactor (circuit breaker for use when necessary). To prevent overheating, the contactor should enlarge the Power Supply capacity of more than 20% of large chemical plant electrical equipment mostly this is the case. We must first consider the mechanical life of electrical contacts and operating mechanism of life belonging to heavy duty and special heavy task of "intermittent periodic duty" equipment selection contactors should be used CJ12 series (especially suitable for winding motor), CJ20 series or series of vacuum contactors, due to derating can greatly improve the electrical contactor life can easily be selected as the starting mcb circuit breaker current of the motor contactor rated current to improve the safety and reliability of production unit.
Power transformer is a static electrical equipment, is used to a certain value of the AC voltage (current) becomes the same frequency as the other one or more different voltage values (current) device.
2015年2月1日星期日
2015年1月29日星期四
electric energy meter Energy-saving technology
AC contactor AC contactor is widely used in low voltage circuits, is a safe, easy to control, CNC Electric volume and a wide range of industrial necessities. Now commonly used in the rated current 63A and above large, medium-capacity AC contactor should more than million Taiwan dollars electric energy meter, its operating system at the time of retention of electromagnetic active power consumed between 10W ~ 100W; reactive power consumed in the Dole circuit breakers spent tens to hundreds of spent between Seoul. The active power consumption distribution is roughly: 65% to 75% of the core, the short-circuit ring 25% to 30%, the coil 3% to 5%. For such a being in the industrialization and urbanization of exchanges and contacts with large country, and the energy needs of the growing tension, saving power resources has become imperative.
Such as the AC contactor solenoid operating system with an appropriate energy-saving technology to its operating system, the original design of electromagnetic ac to dc retention retention, core and short ring can save most of the loss in power, to obtain a high energy-saving efficiency (typically active saving rate> 90%). Moreover, through the Switchgear & Substation transformation can reduce or eliminate noise, reduce the temperature rise of the coil and extend the service life of the contactor.
2015年1月26日星期一
Voltage stabilizer Energy-saving products Categories
AC contactor mainly depends on its energy-saving program works and the corresponding structure processes. Fat suction within the electromagnetic AC contactor by Circuit Breakers constant component F0 and F ~ alternating component composition. Among them:
Constant component: F0 = Fatm / 2 (Fatm = 107 B2 MS / 8π)
Alternating component: F ~ = F0 cos 2ωt.
At work, due to the armature reaction force always been the role of the spring, the contact springs Fr reaction force, the electromagnetic suction averages Fat> Fr; when Fat <Fr armature at the beginning of the release voltage stabilizer, Fat> Fr armature also was attracted state, so Again and again, the armature vibration and noise. At this point in the alternating magnetic core produced by hysteresis loss and eddy current loss will cause the core heat (superposition of silicon can play a role in reducing the eddy current losses). To reduce operating noise is usually electri calmete open in the small capacity of the electromagnetic system yoke ends embedded in a small groove corresponding short-circuit ring, and its role is to be divided into two parts by the core flux, that does not pass through the magnetic flux Φ1 and short-circuit loop the magnetic flux Φ2 through the short-circuit loop, and Φ2 lag Φ1, suction is always greater than the synthesis reaction, thereby reducing the vibration and noise, but also increases the copper loss accordingly.
AC contactor power mainly by the retention power and pull the power of two parts, although larger coil pull starter instant power, but time is very short (tens of ms); working time has been in the retention hold (at this energy loss is mainly concentrated in the state of retention on iron loss). That is why if they can reduce the AC contactor work retention can save energy consumption, CNC Electric according to this principle, the current energy contacts broadly categorized as follows.
2015年1月23日星期五
Voltage stabilizer Coil-saving and Saver
Saver is divided into: capacitive, transformer, duty cycle (change) type. AC contactor Saver corresponding supporting the use of the contactor in the DC state retention operation, air circuit breaker so to save energy. Saver AC contactor solenoid due to electromagnetic energy and the internal device Saver limitations generally applicable to the rated current of 60 ~ 600A AC contactor, lower than 60A AC contactor because the stored electromagnetic solenoid can run in DC maintain its pull; electromagnetic greater than 600A AC contactor can be easily generated so Saver damage internal components voltage stabilizer.
Contactor coil AC passed, it will produce a corresponding inductance, inductive influence of the size of the size of the current in the coil, AC solenoid coil inductance, the core is not closed when the inductance is small, a large current through , which is caused by the coil in the suction power of the largest timely reason. Circuit breaker When the AC contactor pull into the retention time, due to long-term work in the state coupled with the coil power consumption, temperature rise. AC contactor usually work long hours can produce 50 ℃ ~ 60 ℃ degree heat, the summer plus 30 ℃ ~ 40 ℃ ambient temperature of the coil temperature rise faster. Coil long period of high temperature operation, will accelerate the aging and even burned, AC contactor life will be shortened.
According to AC contactor coil power consumption characteristics of fast rise, by reducing the power consumption and temperature to save energy. According to the internal structure, saving coil is divided into: double winding type, current limiting resistor, double winding self-conversion conversion type and location. Works will use energy-saving coil is usually on its pulsating DC coil retention program run: pull winding generally larger diameter, fewer turns, and thus lower impedance, resulting pull current large; retention winding general smaller diameter, number of turns, current transformer the impedance of large, small and therefore holding current. Corresponding increase rectifiers and varistors and film capacitors, the AC contactor is energized to work in DC state, large starting current to ensure a reliable pull-electromagnetic systems, smaller holding current to reduce the retention power, thereby reducing the electrical losses and electromagnetic coil temperature of the system.
Energy-saving AC contactor
According to AC contactor structure, increasing as Power Saver, saving coil, mechanical locking device, electromagnetic system to the remanence (permanent magnet) retention type, etc., can play the energy saving effect. After contact with the tradition of saving energy, such as shown in Table 2.
Traditional CJ10, CJ12, CJ20 AC contactor, for example, for energy saving before and after comparison of the data, reflecting the energy saving effect.
In CJ20 / 400A / 3 year energy savings calculation: saving work properly before the contactor holding power for 180W, priced according to the average electricity tariff by 1 yuan / Kwh meter, working hours 12h / day:
Total power consumption before saving: 0.18Kw × 12h × 365 = 788 Kwh
After saving the total power consumption: 0.006Kw × 12h × 365 = 26 Kwh
Saving (annual electricity): 788Kwh - 26Kwh = 762Kwh
Cost-saving: 762Kwh × 1 元 / Kwh = 762 元
At present, energy-saving AC contactor has a certain market, but not enough popular, traditional exchanges and contacts currently in use on the dominant user. The main reason is the energy-saving type contactors expensive, the user can not accept the one-time investment, to be national policy to electric meter increase efforts on the promotion of energy-saving contacts, promote the wide application of energy-efficient contactors....
2015年1月20日星期二
electric energy meter Thyristor inverter circuit
Thyristor inverter circuit to convert the direct current into alternating current, which corresponds to a reverse process of the rectifier, is defined as an inverter. For example: power transformers The thyristor electric locomotives electric energy meter, when the DC motor as a generator downhill braking operation, the locomotive of potential energy into electrical energy, trans go to the AC grid. Another example is the operation of a DC motor, brake to make it quickly, but also allows the motor as a generator to run the motor kinetic energy into electrical energy, anti-delivered to the grid. The converter operates in inverter state, if the converter is connected to the AC side of the AC power to DC to AC inverter with a Circuit breaker frequency counter to the grid to go, called active inverter.
2015年1月17日星期六
Voltage stabilizer AC inverter circuit Rationale
The DC circuit is called reverse into AC inverter circuit. In certain cases, the same set mcb circuit breaker of thyristor rectifier circuit can make, but for the inverter.
The converter operates in inverter state voltage stabilizer, if the converter is connected to the AC side of the AC power to DC to AC inverter with a frequency counter to the grid to go, called active inverter. If the change is not the AC side current grid connection, but directly to the load, which converts DC to a certain frequency or adjustable frequency alternating current supplied to the load, then called passive inverter. AC frequency control is the use of CNC Electric this principle. Except for the DC reversible active inverter speed control system, but also for AC induction motor rotor Rao line cascade control and other aspects of HVDC.
2 relative concept
Convert alternating current to direct current approach is rectified; and convert DC to AC inverter method.
Rectification, full-wave rectifying circuit is the use of one-way conduction of the diode characteristics, with four diodes connected into a bridge rectifier circuit voltage stabilizer, the input terminal is an AC current, the waveform is a sine wave, the direction of the alternating current, and an output terminal waveform current becomes the same direction, AC Contactors and then through a filter circuit to obtain a DC waveform after filtered.
2015年1月14日星期三
electric energy meter Inverter Classification
Source inverter also has passive inverter. For example, the DC voltage, through a simple, single-phase thyristor bridge type H, H is the output of the cross on each of the electric meter four H's vertical thyristor, electric energy meter, at 34, 14 and 23 were opened to give a positive negative separated the output voltage and current.
The pulse width modulation inverter technology
Basic square wave inverter circuit is simple, but the output voltage waveform harmonic content is too large, but also both the THD (current harmonic distortion) is too large; the phase shift of multiple superimposed small harmonic content inverter output voltage waveform, That THD is small, but the circuit is more complex. The PWM pulse width modulation inverter, both the computer's circuitry, and the output voltage waveform, which has been widely used.
The so-called PWM technology (Pulse Width Modulation, PWM), is made of a reference wave (usually a sine wave, sometimes with a trapezoidal wave or injected zero sequence harmonic Electric transformer sine wave or square wave, etc.) for the modulation wave (electric energy meter), and to N times the frequency of the modulation wave of the triangular wave (sawtooth wave is also sometimes used) of the carrier (Carrier Wave) waveform comparison, the modulation wave is greater than the carrier portion to generate a set of equal amplitude and a width proportional to the modulated waves equivalent rectangular pulse sequence is used to modulate the wave instead of using analog switch, and through the inverter power switch on / off control, the DC power into AC power, this technique is called pulse control inverter technology. Because triangular carrier wave (or sawtooth) vertical section is a linearly varying degrees, so this technique is called pulse control inverter technology. Since the triangular carrier wave (or sawtooth) is vertical width is linear, so that this modulation is linear, when the modulation wave is a sine wave, a rectangular pulse width of the output pulse train changes sinusoidally, this modulation Air circuit breaker technique typically also known as the sinusoidal pulse width modulation (Sinusoida PWM) technology.